QIAsymphony SP/AS instruments

다양한 종류의 샘플에서 6xHis-tagged recombinant protein 또는 nucleic acid를 전자동으로 분리 정제할 수 있습니다

S_0659_IAS_QSYM

✓ 연중무휴 하루 24시간 자동 온라인 주문 처리

✓ 풍부한 지식과 전문성을 갖춘 제품 및 기술 지원

✓ 신속하고 안정적인 (재)주문

QIAsymphony AS

카탈로그 번호 / ID.   9001301

QIAsymphony assay setup module: includes 1-year warranty on parts and labor
InstrumentAccessories
QIAsymphony AS
QIAsymphony SP
QIAsymphony Cabinet
QIAsymphony Cabinet SP/AS
The QIAsymphony SP is intended to be used only in combination with QIAsymphony Kits indicated for use with the QIAsymphony SP for the applications described in the kit handbooks. If used in combination with QIAGEN Kits indicated for use with the QIAsymhony AS instrument, the QIAsymphony AS is intended for the applications described in the respective QIAGEN Kit handbooks. If the QIAsymphony AS instrument is used with kits other than QIAGEN Kits, it is the user’s responsibility to validate the performance of such product combination for any particular application.

✓ 연중무휴 하루 24시간 자동 온라인 주문 처리

✓ 풍부한 지식과 전문성을 갖춘 제품 및 기술 지원

✓ 신속하고 안정적인 (재)주문

특징

  • 사용하기 쉬운 새로운 형태의 미리 용액을 채운 reagent cartridge 형태
  • Run당 1에서96개 샘플까지 원하는 만큼 처리가능
  • Large sample volumes으로 high yields와 sensitivity 획득
  • 혁신적인 design을 통한 안전하고 진보된 실험 과정을 제공함
  • 가장 최신의 service와 support를 위한 QIAGEN Device Management

제품 세부 정보

With a dedicated range of QIAsymphony Kits, the QIAsymphony SP enables sample preparation of DNA, RNA, bacterial and viral nucleic acids, and 6xHis-tagged protein from a wide range of starting materials. The QIAsymphony AS extends the capabilities of the QIAsymphony SP by integrating automated PCR assay setup, which, in combination with the Rotor-Gene Q and QIAGEN real-time and end-point PCR kits, enables you to complete your automated PCR workflow and maximize your efficiency.

원리

The QIAsymphony SP can save you time by processing 1–96 samples — in batches of 24 — with sample volumes up to 2 ml. A dedicated range of QIAsymphony Kits increase laboratory efficiency since just a few kits in combination with optimized protocols cover an extensive range of starting materials and applications. QIAsymphony technology combines the speed and efficiency of silica- or Ni-NTA-based purification with the convenient handling of magnetic particles.

Dedicated QIAsymphony Kits for a wide range of starting materials
Kits Starting material and amount
QIAsymphony DNA Kit Purification of DNA from up to 1000 µl human whole blood, 400 µl buffy coat, 50 mg tissue (including FFPE tissue), or 1 x 107 cells, and purification of viral nucleic acids from blood
QIAsymphony DSP DNA Kit Purification of DNA from up to 1000 µl human whole blood, 400 µl buffy coat, tissue (including FFPE tissue), bacterial and cell cultures, and purification of viral nucleic acids from blood for in vitro diagnostic use
QIAsymphony DNA Investigator Kit Purification of reference and casework samples for human identity testing and forensics
QIAsymphony DSP Virus/Pathogen Kit  Purification of viral nucleic acids from plasma, serum, and CSF, and viral nucleic acids and bacterial DNA from respiratory and urogenital samples for in vitro diagnostic use
QIAsymphony DSP AXpH DNA Kit Purification of DNA from liquid-based cytology samples using AXpH technology, for in vitro diagnostic use
QIAsymphony RNA Kit Purification of total RNA and miRNA from up to 50 mg tissue (including FFPE tissue) or 1 x 107 cells
QIAsymphony PAXgene Blood RNA Kit* Purification of intracellular RNA (including miRNA) from 2.5 ml human whole blood collected in PAXgene Blood RNA Tubes
QIAsymphony Ni-NTA Native Kit Purification of 6xHis-tagged native proteins from up to 5 ml E. coli or up to 2.5 x 107 eukaryotic cells
QIAsymphony Ni-NTA Denaturing Kit Purification of 6xHis-tagged denatured proteins from up to 5 ml E. coli or up to 2.5 x 107 eukaryotic cells
QIAsymphony mericon Bacteria Kit Purification of bacterial DNA from 500 μl enrichment culture
QIAsymphony Certal Kits Purification of residual host cell DNA and viral NA from bioprocess purification buffer, cell culture supernatant samples, and vaccine preparations
* Up to 72 samples can be processed per run.
  

Extending the QIAsymphony SP with the QIAsymphony AS results in a fully integrated system that can automate complete workflows. Manual pipetting steps prone to human error are eliminated, making this system ideal for laboratories that perform complex PCR assays on a day-to-day basis. The QIAsymphony AS provides active cooling of reagents, eluates, and assays, enabling safe and reproducible assay setup. The QIAsymphony AS enables setup of multiple assays per run or sample and supports artus products and QIAGEN PCR and RT-PCR kits. A customization service is available for in-house assays.

With innovative design features, the QIAsymphony SP/AS instruments deliver exceptional process safety and standardization. Tip guards minimize the risk of cross-contamination and built-in UV lamps provide effective worktable decontamination. Bar code reading of samples and reagents enables full sample tracking throughout the entire purification and assay setup procedure. Chronological electronic documentation of results is provided, including information about sample IDs, their positions, and the lot number and expiry date of sample preparation and PCR reagents. Multi-level user management provides a record of which user was responsible for sample processing. Electronic result files can be automatically printed via a networked printer, or downloaded using a USB stick for archiving purposes.

The QIAsymphony Cabinet SP/AS (see figure " QIAsymphony Cabinet SP/AS") is specifically designed for correct positioning of the QIAsymphony SP/AS instruments. The QIAsymphony Cabinet SP/AS comprises two separate parts: one for the QIAsymphony SP and one for the QIAsymphony AS. If you have QIAsymphony SP and QIAsymphony AS instruments, you need both cabinet parts, which are then positioned side by side. If you just have a QIAsymphony SP instrument, only the QIAsymphony Cabinet SP is required. The QIAsymphony Cabinet SP and the QIAsymphony Cabinet AS each contain a waste compartment into which used tips from the worktable can be ejected.

 

그림 참조

절차

The QIAsymphony SP is ready-to-run and requires only minimal installation. Laboratories already operating a QIAsymphony SP can easily upgrade their system onsite with a QIAsymphony AS module. The QIAsymphony AS directly interfaces with the QIAsymphony SP. To reduce manual handling steps and minimize the risk of sample contamination, samples processed on the QIAsymphony SP can be transferred automatically to the QIAsymphony AS (integrated operation). For extra flexibility, the QIAsymphony SP and AS can also be operated independently. Samples that have been processed earlier in the day, or that have been processed on a different QIAsymphony SP, can be manually transferred to the QIAsymphony AS (see figure " QIAsymphony workflows").

Sample preparation and assay setup runs are defined using the touchscreen. Simply load drawers with the required samples, reagents, and consumables. When each drawer is closed, a detailed inventory scan is performed. This ensures that the worktable is correctly set up for the selected protocols. After sample preparation, either remove purified nucleic acids/proteins from the eluate drawer or automatically transfer eluates to the QIAsymphony AS via the transfer module for assay setup. After assay setup, assays can be transferred directly to a real-time PCR cycler for analysis.

The sample input drawer accommodates a wide range of sample input formats to suit varying workflows and sample preparation requirements. Bar code–labeled primary and secondary sample tubes (diameter 10–16.9 mm), microtiter plates, and blocks are supported. Continuous loading in batches of up to 24 samples plus internal controls, and the option to assign different protocols to each batch, delivers increased efficiency and walkaway time. The QIAsymphony AS enables setup of single or multiple PCRs per run or sample, splitting of eluates for panel testing, and active cooling of eluates, reagents, and PCRs. A choice of output adapters enables use of different real-time PCR cyclers (e.g., Rotor-Gene Q, 96-well cyclers, 32-capillary cyclers). To use the Rotor-Gene Q for detection, simply set up your PCRs in Strip Tubes or Rotor-Discs.

QIAsymphony Kits are safe and exceptionally easy to use. Ready-to-run, bar code-labeled reagent cartridges are prefilled with all reagents required for the purification procedure, including accessory enzymes (see figure " Prefilled, sealed reagent cartridges"). Worktable setup is rapid and saves you valuable time. Simply place up to 2 reagent cartridges in the QIAsymphony drawer. The reagent cartridges can be from the same or different kits, enabling different purification procedures to be performed within the same run of 96 samples. Reagent cartridges are automatically opened by the instrument, and reagent volumes only for the selected number of samples are used, giving you complete cost control.

그림 참조

응용 분야

The QIAsymphony SP/AS instruments are suitable for laboratories performing applications, such as:

  • Molecular diagnostics and biomedical research
  • Human identity testing
  • Veterinary applications
  • Biosecurity research
  • Life science applications, such as genomics and proteomics

소프트웨어

QIAsymphony operating software guides the user step-by-step through setting up a sample preparation or assay setup run, with options to select and adapt standardized protocols. Required volumes of buffers, reagents, master mix, and controls are automatically calculated, and the user is informed of the number and type of consumables to be loaded. Transfer of sample loading information from the QIAsymphony SP to the QIAsymphony AS is convenient and reduces the number of steps required for assay definition.

The QIAsymphony SP/AS instruments provide standardized communication interfaces. Work lists and rack files can be imported to the instruments, enabling automatic run definition before samples are received in the laboratory. After assay setup, sample lists can be exported to selected real-time PCR cyclers. This bi-directional data exchange allows integration of QIAsymphony SP/AS instruments into laboratory information management systems (LIMS).

서비스

Have your throughput demands increased? Do you want to expand your application range or further streamline workflows? Do you need to manage more complex samples? Do you need improved connectivity?

If the answer to any of these questions is yes, then QIAGEN’s trade-in/trade-up program is just right for you!

QIAGEN makes it easy to keep up to speed with the latest automation and sample processing technologies. Simply exchange an old instrument for a new one. Improve your efficiency by trading in a competitor instrument or trading up with an older QIAGEN instrument.

Learn more about trade-in/trade-up opportunities.

지원되는 데이터 및 수치

사양

특징사양
power100–240 V AC, 50–60 Hz, 1400 VA, mains supply voltage are not to exceed 10% of nominal supply voltages
inputvolumeQIAsymphony SP — minimum input volume: 200 µl (application dependent)
operatingtemperature15–32°C
pollutionlevel2
placeofoperationFor indoor use only
elutionvolumeQIAsymphony SP — 30–500 µl (application dependent)
kitsorapplicationpacksdesignedforthisinstrumentQIAsymphony SP — QIAsymphony DSP Virus/Pathogen Kits and other QIAsymphony Kits; QIAsymphony AS — artus QS-RGQ Kits (not available in all countries), Rotor-Gene Kits and other QIAGEN real-time and end-point PCR kits
overvoltagecategoryII
humidityRelative humidity of 15–75% (noncondensing); maximum 75% relative humidity for temperatures up to 31°C, decreasing linearly to 50% humidity at 32°C
instrumentdimensionsQIAsymphony SP, 128 x 103 x 73 cm; QIAsymphony AS, 59 x 103 x 73 cm; QIAsymphony SP/AS (integrated operation), 185 x 103 x 73 cm
processingAutomated
protocolsmainapplicationonthisinstrumentQIAsymphony SP — Purification of DNA, RNA, and bacterial and viral nucleic acids from a wide range of starting materials; QIAsymphony AS — PCR setup.
storagetemperature5–40°C in manufacturer's package
technologyQIAsymphony SP — QIAGEN magnetic-particles chemistry
transportationtemperature–25 to 70°C in manufacturer's package
weightQIAsymphony SP, 175 kg; QIAsymphony AS, 90 kg; QIAsymphony SP/AS (integrated operation), 265 kg
altitudeUp to 2000 m (6500 ft)

서비스 계획

QIAsymphony SP/AS, Premium Agreement

Cat. No. / ID. / ID.   9242508

On-site QIAsymphony SP/AS instrument repair, including travel, labor and parts, for a period of one year. Response time of next business day. Includes one Preventive Maintenance or Inspection Service during the Premium Agreement period..

QIAsymphony SP, Premium Agreement

Cat. No. / ID. / ID.   9241208

On-site QIAsymphony SP instrument repair, including travel, labor and parts, for a period of one year. Response time of next business day. Includes one Preventive Maintenance or Inspection Service during the Premium Agreement period.

QIAsymphony AS, Premium Agreement

Cat. No. / ID. / ID.   9244820

On-site QIAsymphony AS instrument repair, including travel, labor and parts, for a period of one year. Response time of next business day. Includes one Preventive Maintenance or Inspection Service during the Premium Agreement period.

QIAsymphony SP/AS, Full Agreement

Cat. No. / ID. / ID.   9242507

On-site QIAsymphony SP/AS instrument repair, including travel, labor and parts, for a period of one year. Response time of two business days. Includes one Preventive Maintenance or Inspection Service during the Full Agreement period.

QIAsymphony SP, Full Agreement

Cat. No. / ID. / ID.   9241207

On-site QIAsymphony SP instrument repair, including travel, labor and parts, for a period of one year. Response time of two business days. Includes one Preventive Maintenance or Inspection Service during the Full Agreement period.

QIAsymphony AS, Full Agreement

Cat. No. / ID. / ID.   9244819

On-site QIAsymphony AS instrument repair, including travel, labor and parts, for a period of one year. Response time of two business days. Includes one Preventive Maintenance or Inspection Service during the Full Agreement period.

QIAsymphony SP, Preventive Subscription

Cat. No. / ID. / ID.   9243545A

One on-site Preventive Maintenance or Inspection Service visit for the QIAsymphony SP, including travel, labor and parts. Includes a 10% discount on repair services during the Preventive Subscription period.

QIAsymphony SPAS Preventive Subscription

Cat. No. / ID. / ID.   9243546A

One on-site Preventive Maintenance or Inspection Service visit for the QIAsymphony SP/AS, including travel, labor and parts. Includes a 10% discount on repair services during the Preventive Subscription period.

QIAsymphony AS, Preventive Subscription

Cat. No. / ID. / ID.   9244817A

One on-site Preventive Maintenance or Inspection Service visit for the QIAsymphony AS, including travel, labor and parts. Includes a 10% discount on repair services during the Preventive Subscription period.

리소스

Application/Protocol Documents (27)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
For use with the QIAsymphony AS (software version 4.0 or higher)
Supporting Software and Tools (2)
For QIAsymphony software version 5.0.4
Work List Tool
SOFTWARE (1MB)
For QIAsymphony Software version 5.0
Protocol Files (8)
For use with the QIAsymphony SP/AS instruments (software version 4.0 or higher)
For use with the QIAsymphony SP/AS instruments (software version 4.0 or higher)
For use with the QIAsymphony SP instruments (software version 4.0 or higher)
For use with the QIAsymphony SP/AS instruments (software version 4.0 or higher)
For use with the QIAsymphony SP/AS instruments (software version 4.0 or higher)
For use with the QIAsymphony SP/AS instruments (software version 5.0 or higher)
For use with the QIAsymphony SP/AS instruments (software version 4.0 or higher)
Instrument User Manuals (4)
For use with QIAsymphony SP/AS instruments (software version 5.0)
For use with QIAsymphony SP/AS instruments (software version 5.0)
For use with QIAsymphony SP/AS instruments (software version 5.0)
For use with QIAsymphony SP/AS instruments (software version 5.0)
Safety Data Sheets (1)
Download Safety Data Sheets for QIAGEN product components.
Instrument Technical Documents (10)
QIAsymphony Cabinet SP/AS documents
Differences between QIAsymphony software versions
For use with QIAsymphony SP/AS instruments (software version 5.0)
QIAsymphony SP recovery procedures for DNA Investigator applications for software version 4.0 and HID 1.0
QIAsymphony SP recovery procedures for DNA Investigator applications for software version 4.0 and HID 1.0
QIAsymphony Cabinet SP/AS document
QIAsymphony SP recovery procedures for DNA Investigator applications for software version 4.0 and HID 1.0
Software document for QIAsymphony software version 4.0.1
QIAsymphony SP recovery procedures for DNA Investigator applications for software version 4.0 and HID 1.0
Brochures & Guides en (4)
For automated purification of nucleic acids or 6xHis-tagged recombinant proteins from a wide variety of sample types
Advanced sample collection, automation and STR solutions for kinship testing
Labware Files and Documents (3)
Labware package SOW-516-0-08 for use with the QIAsymphony SP/AS instruments (software version 5.0)
For use with software version 5.0 or higher
Certificates of Analysis (1)